Key points
- The authors propose COMBIO, a pipeline that distils laboratory-panel machine-learning models into a compact closed-form biomarker, targeting the difficulty of interpreting and operationalizing such models.
- Shapley additive explanation values from a gradient-boosted reference model rank five candidate measurements and guide eligible exponent signs.
- An exhaustive search over small integer exponents from minus two to two, with two to four nonzero terms, selects the formula on an inner validation set before evaluation on the reserved test set.
- Across the six test sets, COMBIO's AUROC differed by at most 0.03 from logistic regression using the five candidate laboratory measurements.
- The hospital mortality composite achieved an AUROC of 0.698 in the external eICU database, and a version restricted to widely available measurements achieved an AUROC of 0.786 in a cohort covering 92% of admissions.
- The authors state that the multiplicative representation provides compactness rather than additional accuracy, and local validation and recalibration are required before clinical use.